Rack-Level Liquid Cooling
Ingrasys offers a complete line of rack-level liquid cooling solutions based on where the heat is exhausted in the data center. These solutions include options for exhausting heat entirely into the data center air, into the facility water, or a combination of both. Whether your data center is traditionally air cooled or liquid cooled, Ingrasys delivers high performance cooling solutions that suit your needs.
Advantage
Higher Power Density
Employ direct liquid cooling technology to efficiently remove heat from heat-producing components such as CPUs or GPUs, enabling high-power chips to operate at maximum performance.
Great Cooling Capacity
Due to the close contact between the cooling liquid and the heat source, liquid-cooled systems delivers great cooling capacity, ensuring efficient heat dissipation while supporting compute-intensive applications
High Serviceability
The blind-mate connector ensures simple connections and front servicing of all rack components, including servers, hot-swappable fans, pumps, and PSUs of the RPU/CDU.
Management Control System
Integrated control system provides monitoring and control of liquid/air flow rate, liquid/air temperature, pump speed, and RDHx fan speed
Liquid-to-Air Solution
-
Scenario 1: All Heat to Air (Model: LA0452)
*RPU (Reservoir and Pumping Unit)
-
Scenario 2: All Heat to Side Car (Model: LA0703)
*RPU (Reservoir and Pumping Unit)
Product Number | LA0452 |
Cooling Mechanism |
Air-Assisted Liquid Cooling, All Heat to Data Center Air |
Rack Size |
ORv3 Liquid Cooling Rack, 600mm x (1200+305)mm x 2295mm |
Cooling Capability |
45kW with 38kW (85%) Heat Dissipating through Liquid |
Computing Node |
RU 19" /OU 21" Server Compatible |
Cooling Kits |
|
Redundancy | 9+1 Fans 1+1 Pumps 2+1 PSUs |
Serviceability |
|
Product Number | LA0703 |
Cooling Mechanism |
Air-Assisted Liquid Cooling, All Heat to Data Center Air |
Rack Size |
ORv3 Liquid Cooling Rack, 600mm x 1068mm x 2295mm |
Cooling Capability | 70kW |
Computing Node |
Flexible (Depending on the Connected IT Rack) |
Rack Deployment | Support Multiple Racks |
Cooling Kits |
|
Redundancy | 15+1 Fans 2+1 Pumps 3+3 PSUs |
Serviceability |
|
Liquid-to-Liquid Solution
-
Scenario 1: In-Rack CDU (Model: LL1000)
*CDU (Cooling Distribution Units)
PHE (Plate Heat Exchanger) -
Scenario 2: In-Row CDU (Model: LL6003/LL13003)
*CDU (Cooling Distribution Units)
PHE (Plate Heat Exchanger)
Product Number | LL1000 |
Cooling Mechanism |
Liquid-to-Liquid and Air-to-Air, Main Heat to Facility Liquid |
Rack Size |
ORv3 Liquid Cooling Rack, 600mm x 1068mm x 2295mm |
Cooling Capability |
100kW (80% Heat Dissipated through the Liquid) |
Computing Node |
RU 19" /OU 21" Server Compatible |
Redundancy |
1+1 Pumps |
Serviceability |
|
Product Number | LL6003/LL13003 |
Cooling Mechanism |
Liquid-to-Liquid, Main Heat to Facility Liquid |
Rack Size |
LL6003: 800mm x 1200mm x 2100mm LL13003: 900mm x 1250mm x 2160mm |
Cooling Capability |
LL6003: 600kW LL13003: 1300kW |
Computing Node | Flexible (Depending on the Connected IT Rack) |
Redundancy |
N+1 Pumps |
Serviceability |
Hot-swappable Pumps |
Management Control |
|